Skip to main content
ENERGY, SOLAR & MANUFACTURINGMODBUS & MQTT TELEMETRY

Industrial IoT Telemetry for Commercial Solar, Tubewells & Generators

OT-isolated Modbus RTU/RS485 edge gateways, store-and-forward MQTT over TLS pipelines, and TimescaleDB fault analytics engineered for harsh field sites.

CASDO Technologies architects industrial telemetry systems connecting commercial solar inverters, high-horsepower agricultural water pumps, and standby diesel generators to encrypted cloud observability. Modeled directly on real facility profiles—such as a 44 kW solar array driving a 50 HP inverter and 40 HP tubewell motor—our architecture prioritizes electrical isolation, local outage buffering, and safe human-authorized alerting.

Inspect Case Studies
Industrial solar inverter and generator Modbus MQTT IoT telemetry dashboard engineered by CASDO Technologies
Reference Load Profile
44 kW Solar · 50 HP Inverter · 40 HP Motor
Field Protocols
Modbus RTU/RS485 · MQTT over mTLS
Telemetry Warehouse
PostgreSQL + TimescaleDB Hypertables
Control Interlock Policy
Hardware-Protected · Alert-First Safety

Operational Bottlenecks Solved

  • Unmonitored solar inverter faults, dry-run pumps, and generator fuel anomalies cause costly equipment burnouts.
  • Exposing Modbus TCP/RS485 industrial buses directly to public networks creates severe operational security risks.
  • Intermittent rural cellular coverage causes blind spots when telemetry devices lack local flash store-and-forward buffers.
REFERENCE ENGINEERING ARCHITECTURE

Layered System Blueprint

Isolated OT Edge Polling

Galvanically isolated RS485 Modbus RTU polling via ESP32-S3 or industrial Linux gateways with read-only register whitelists by default.

Store-and-Forward Transport

Outbound-only MQTT over mutual TLS (mTLS) with local ring-buffer persistence during ISP outages and monotonic timestamp replay.

Time-Series Storage & Analytics

PostgreSQL + TimescaleDB hypertables with continuous aggregates for kW yield, phase voltage imbalance, current draw, and runtime logs.

Safety-First Fault Alerting

Real-time threshold rules dispatching SMS/WhatsApp/dashboard alerts while prohibiting unsafe autonomous remote restarts of heavy rotating loads.

PRODUCTION TECHNOLOGY STACK

Verified Frameworks & Runtimes

Modbus RTU / RS485MQTT over TLSESP32 / Industrial LinuxTimescaleDBFastAPIWebSockets
VERIFIED ENGINEERING EVIDENCE

Deployed Systems & Technical Documentation

TECHNICAL QUESTIONS & ANSWERS

Frequently Asked Questions

Do CASDO IoT gateways require opening inbound firewall ports at our factory or farm?

No. Edge gateways initiate outbound-only MQTT over TLS connections to the broker, eliminating inbound attack surfaces on site routers and cellular modems.

What happens to sensor readings during a power or cellular outage?

Gateways buffer timestamped telemetry batches in local non-volatile flash memory and flush them sequentially into TimescaleDB once connectivity restores.

RELATED SOLUTIONS

Related Engineering Solutions

Explore purpose-built industry and capability architectures engineered by CASDO Technologies.

View All Solutions